Following the installation of pipe penetrations through a vertical shaft wall, groundwater and silty sand began entering the shaft around the penetrations.
The uncontrolled ingress created difficult working conditions, increased cleanup requirements, and threatened to disrupt ongoing installation activities. The customer needed a fast and effective way to stop the water and silt without excavation, major structural modifications, or significant delays to the project.
Poly-Mor Canada used geotechnical polyurethane injection to stop the active ingress and stabilize the soils behind the shaft walls.
Using copper injection probes inserted through access holes in the wall panels, hydrophobic polyurethane was injected into the surrounding soils. The expanding material filled subsurface voids, displaced groundwater, and stabilized the silty sand while creating a protective curtain-grouted barrier behind the shaft wall.
The injection program targeted an area approximately 12 feet by 8 feet around each pipe penetration. By treating the surrounding soils rather than simply sealing the visible entry points, the solution addressed water and silt pathways beyond the penetrations themselves.
The ingress of groundwater and silty sand was successfully controlled, creating a safer, cleaner, and more manageable environment within the shaft.
For the customer, the benefits were clear: